WARNING: Installation and removal of the Module must 
be carried out by qualified personnel only. Before installing 
the Module into a unit, you must first disconnect the unit 
from the mains power supply. For full safety instructions, 
refer to the user guide that accompanies the unit.
AVERTISSEMENT: Confiez l'installation et la dépose de ce 
Module à un personnel qualifié. Avant d'installer ce 
Module dans un groupe, vous devez au préalable 
débrancher ce groupe de l'alimentation secteur. Pour 
prendre connaissance des consignes complètes de sécurité, 
consultez le guide utilisateur qui accompagne ce groupe.
VORSICHT: Die Installation und der Ausbau des Moduls 
darf nur durch Fachpersonal erfolgen. Vor dem Installieren 
des Moduls in einem Gerät muß zuerst der Netzstecker 
des Geräts abgezogen werden. Vollständige 
Sicherheitsanweisungen sind dem Benutzerhandbuch des 
Geräts zu entnehmen.
WARNING: When the Module is inserted into the switch, 
the captive screws securing the Module must be tightened 
with a suitable tool. Keep the blanking plate and the 
fixings in a safe place. If you remove the Module at any 
time, you must then replace the blanking plate.
AVERTISSEMENT: Quand le Module est inséré dans le 
commutateur, visser le module, en le securisant fortemant 
avec un outil adapté. Conservez la plaque d'obturation et 
les fixations en lieu sûr. Si vous retirez le Module à tout 
instant, vous devez alors replacer la plaque d'obturation.
VORSICHT: Beim Einsetzen des Moduls in dem Switch 
sind die unverlierbaren Schrauben mit einem passenden 
Werkzeug festzuziehen. Die Distanzplatte und die 
Befestigungselemente an einem sicheren Ort aufbewahren. 
Beim Austausch des Moduls ist auch die Distanzplatte zu 
ersetzen.
Handling the Module
The Module can be easily damaged by electrostatic 
discharge. To prevent damage, observe the following:
„
Always wear an anti-static wristband connected to a 
suitable earth point.
„
Do not remove the Module from its packaging until 
you are ready to install it into a Switch.
„
Do not touch any of the pins, connections or 
components on the Module.
„
Handle the Module only by its edges and front panel.
„
Always store or transport the Module in anti-static 
packaging.
CAUTION: The Interconnect Module is not hot-swappable 
or hot-insertable. Always make sure that the Switch is 
powered down and disconnected from the mains before 
installing or removing a Module. Use the following 
instructions when installing or removing a Module.
Installing the Module into a Switch
To install the Module:
Ensure that the power supply and the backbone 
connection cables are disconnected from the Switch. 
Always wear an anti-static wristband connected to a 
suitable earth point.
Undo the three screws securing the blanking plate at the 
rear of the Switch using a suitable screwdriver. Do not 
remove any other screws from the rear of the Switch.
Remove the blanking plate. 
Hold the Module so that the text on the front panel is 
upright and insert it into the Switch, ensuring the 
connectors are fully engaged (see Figure 2). Make sure the 
Module is pushed fully in.
Secure the Module by tightening the three captive screws 
with a suitable screwdriver.
Keep the blanking plate and screws in a safe place. If you 
remove the Module at any time, you must replace the 
blanking plate to prevent dust and debris entering the 
Switch. Replacing the blanking plate will also help circulate 
cool air through the Switch.
Removing the Module from a Switch
To remove the Module:
Ensure that the power supply and the backbone 
connection cables are disconnected from the Switch. 
Always wear an anti-static wristband connected to a 
suitable earth point.
Undo the three captive screws on the Module with a 
suitable screwdriver. Do not remove any other screws from 
the rear of the Switch.
Remove the Module.
If you are not fitting another Module immediately, you 
must replace the blanking plate to ensure that dust and 
debris do not enter the Switch. Replacing the blanking 
plate will also help circulate cool air through the Switch.
Figure 2   Installing the Module
I
NSTALLING
 
AND
 R
EMOVING
 
THE
 M
ODULE
!
!
S/N: XXX
X/7XXXXXXXX
X
S/N:
XXXX/7XXXXXXXXX
3C17716
XRN Inter
connect M
odule
3C17716
XRN Inter
connect Module
Console
(max) 19200,8,1,N
Console
(max) 19200,8,1,N
Unit 1
Unit 1
Unit 2
Unit 2
Activ
ity
Activity
Statu
s
Status
3C17700
MAC A
ddr: X
XXXX
XXXX
XXX
Switch 4900
Seria
l No X
XX/X
XXXX
XXXX
X
SUPPLY
 DATA
V-
90 - 2
40
Hz
50/6
0
A
INPUT
V
27
A Ma
x
12
REFER
 TO IN
STRUC
TION
MANU
AL FO
R COR
RECT
I
4.5
2