Setting Callback dial strings 
The Sentry integrated Modem supports definition of up to 30 callback dial strings.   
The AT&Z command is used to set a dial string.  Dial strings may be up to 34 characters and may 
include other AT commands. 
To set a Callback dial string: 
After successfully logging into the modem with the Setup password, type at&z, followed by the 
memory location (0-29), =atdt (tone-dial) or dp (pulse-dial) and the number/dial string.  Press Enter
Examples 
The following command sets the dial string for memory location 0 to tone-dial, 1-775-284-2000: 
at&z0=atdt17752842000<Enter> 
The following command sets the dial string for memory location 29 to pulse-dial, 1-775-555-1212: 
at&z29=atdp17755551212<Enter> 
To verify and reset the modem with the configured dial strings: 
Type at&v and press Enter
Type atz and press Enter
NOTE:  Callback Security dial strings may also be configured to allow a user to bypass the stored number with a dynamic 
entry or make a direct connection without a callback.  Server Technology does not recommend the use of these options as 
they have a negative effect on security for the modem connection. 
To enable these options additional characters are required when setting a dial string: 
 
+ 
enables optional dynamic callback dial string entry 
 
- 
enables optional direct connection without a callback 
 
,??? 
Used with ‘+’ enables optional use of dynamic extension entry 
Examples 
The following command enables dynamic callback string and extension entry where the extension length is 5 characters: 
 at&z0=+atdt17752842000,?????<Enter> 
The following command enables direct connection without a callback: 
 at&z0=-atdp17755551212<Enter> 
Resetting a Callback memory location 
The AT#CBR command is used to reset the dial string and password for any given memory location. 
To reset a Callback  memory location: 
After successfully logging into the modem with the Setup password, type at#cbr, followed by the 
memory location (0-29), and press Enter.  
Type atz and press Enter to reset the modem with the new settings. 
Example 
The following commands reset memory location 0: 
at#cbr0<Enter> 
OK 
atz<Enter> 
OK 
8 
•   Operations 
Sentry Global Security Modem 
 
 
Installation and Operations Manual