READ RECORD
192
GET RESPONSE
214
UPDATE BINARY
220
UPDATE RECORD
242
STATUS
Identifier for an elementary data file on SIM, if used by 
Parameter to be passed on by the MC55 to the SIM. 
0...255
Parameter to be passed on by the MC55 to the SIM. 
0...255
Parameter to be passed on by the MC55 to the SIM. 
0...255
Information which shall be written to the SIM (hexadecimal character format). 
Status information from the SIM about the execution of the actual command. It is returned in both cases, on suc-
cessful or failed execution of the command. 
0...255
Status information from the SIM about the execution of the actual command. It is returned in both cases, on suc-
cessful or failed execution of the command. 
0...255
Response data in case of a successful completion of the previously issued command. 
"STATUS" and "GET RESPONSE" commands return data, which gives information about the currently selected
elementary data field. This information includes the type of file and its size. 
After "READ BINARY" or "READ RECORD" commands the requested data will be returned. 
 is empty after "UPDATE BINARY" or "UPDATE RECORD" commands. 
<fileID>
(num)
<P1>
(num)
<P2>
(num)
<P3>
(num)
<data>
(str)
<sw1>
(num)
<sw2>
(num)
<response>