Toshiba AS311 Manual De Usuario

Descargar
Página de 66
  
User’s 
Manual 
53
 
6. RAS Information 
 
 
 
6.2  Buffer memory information 
 
 
 
Various RAS information are stored in the AS311’s buffer memory. These information 
 
 
can be read by READ instruction. When some abnormality has occurred, check these 
  
information. 
 
 6.2.1 
Module 
status 
 
 
 
Address 4 of the buffer memory stores the AS311 module status.  
 
 
F E D C B A 9 8 7 6 5 4 3 2 1 0 
RDY 
ERR 
0 0 0 0 0 0 
Error 
code 
 
 
Bit F 
RDY (Ready) 
1 = operating normally 
0 = under initialization or error state 
Bit E 
ERR (Error) 
1 = error state 
0 = no error (normal) 
Bit 7-0 
Error code 
Shows the detected error item if ERR is 1. 
See the table below (H00 when normal) 
 
 
Error 
code 
Type of error 
Description 
Status 
H01 
CPU error 
CPU error has been detected 
during initialization. 
Operation is stopped. 
H02 
ROM error 
ROM error has been detected 
during initialization. 
Operation is stopped. 
H03 
RAM error 
Work RAM error has been 
detected during initialization. 
Operation is stopped. 
H04 Buffer 
memory 
error 
Buffer memory error has been 
detected during initialization. 
Operation is stopped. 
H05 Switch 
setting 
abnormal 
Switch setting abnormality has 
been detected during 
initialization. 
Operation is stopped. 
H10 Watchdog 
timer error 
Watchdog timer error has 
occurred during operation. 
Operation is stopped. 
Cold reset will be 
effective. 
H11 Trap 
interrupt 
error 
Trap interrupt has occurred by 
detecting illegal instruction 
during operation. 
Operation is stopped. 
Cold reset will be 
effective. 
H12 Buffer 
memory 
time-out error 
Buffer memory time-out has 
occurred during operation. 
Operation is stopped. 
Cold reset will be 
effective.