Toshiba DEV002Z-1 Manual De Usuario

Descargar
Página de 37
E6581281 
f
- 6 -
2.4.  DeviceNet LED indicator
The DEV002Z 
option
 has a two-color (red and green) LED as a means of indicating the
MNS (module/network status), which works basically in accordance with DeviceNet
specifications.
LED
Status
Item displayed
Off
Not Powered/Not On–line
Device is not on-line.
- The DEV002Z has not completed the Dup_MAC_ID test yet.
- The DEV002Z may not be powered.
Lights
green.
Device Operational AND
 On–line, Connected
The DEV002Z is operating in a normal condition and the DEV002Z
is on-line with connections in the established state.
Flashes
green.
Device Operational AND
  On–line, Not Connected
or
Device On–line AND
  Device needs commissioning
The DEV002Z is operating in a normal condition and the DEV002Z
is on-line with no connections in the established state.
- The DEV002Z has passed the Dup_MAC_ID test, is on-line, but
has no established connections to other nodes.
- Configuration missing, incomplete or incorrect.
Flashes
red.
Minor Fault and/or
 Connection Time–Out
Recoverable fault and/or one or more I/O Connections are in the
Timed-Out state.
Lights red.
Critical Fault or
  Critical Link Failure
The DEV002Z has an unrecoverable fault; may need replacing.
Failed communication device. The DEV002Z has detected an error
that has rendered it incapable of communicating on the network
(Duplicate MAC ID, or Bus-off).
Flashes red
and green
alternately.
Communication Faulted and
  Received an Identify Comm
Fault Request - Long Protocol
A specific Communication Faulted device. The DEV002Z has
detected a Network Access error and is in the Communication
Faulted state.
The DEV002Z has subsequently received and accepted an Identify
Communication Faulted Request - Long Protocol message.