Toshiba G7 Manual De Usuario

Descargar
Página de 221
G7 ASD Operation Manual
45
Monitor Mode
The Monitor mode allows the user to monitor motor performance variables, control settings, and 
configuration data during motor operation. There are 46 items that may be monitored from this mode. The 
items are listed and described below.
Note:
The Monitor mode is a read-only mode. The settings cannot be changed from the 
Monitor mode. For information on how to change the values, see the section titled 
Running Frequency — Displays the G7 Output Frequency.
Frequency Reference — Displays the Frequency Setpoint.
Output Current — Displays the Output Current as a percentage of the rated capacity of the G7.
Bus Voltage — Displays the Bus Voltage as a percentage of the rated capacity of the G7.
Output Voltage — Displays the Output Voltage as a percentage of the rated capacity of the G7.
Input Signal Status — Displays the status of the discrete input lines of the Control Terminal Strip.
Out1 Out2 FL — Displays the status of the discrete output lines of the Control Terminal Strip.
Timer — Displays the Cumulative Run Time in hours.
Postcomp Frequency — Displays the Output Frequency after the application of the slip 
compensation correction value.
Feedback (inst.) — Provides a status of the Real Time Feedback in Hz.
Feedback (1 second) — Provides a status of the 1-Second Averaging feedback in Hz.
Torque  Displays the Output Torque as a percentage of the rated capacity of the G7.
Torque Reference  Displays the Torque Reference as a percentage.
Torque Current  Displays the current being used to produce torque.
Excitation Current  Displays the current required to produce the excitation field.
PID Value  Displays the PID feedback value in Hz (Proportional-Integral-Derivative).
Motor Overload  Displays the Motor Overload value as a percentage of the rated capacity of the 
motor.
ASD Overload — Displays the ASD Overload as a percentage of the rated capacity of the G7.
DBR Overload — Displays the DBR Overload value as a percentage of the Dynamic Braking 
Resistor
 capacity.
Motor Load — Displays the Motor Load in real time as a percentage of the rated capacity of the 
motor.
ASD Load — Displays the ASD Load as a percentage of the rated capacity of the G7.
DBR Load — Displays the DBR Load as a percentage of the Dynamic Braking Resistor capacity.
Input Power — Displays the Input Power in Kilowatts (Kw).
Output Power — Displays the Output Power in Kilowatts (Kw).
Peak Current — Displays the Peak Current since the last start was initiated. The current is 
displayed as a percentage of the rated capacity of the G7.
Peak Voltage — Displays the Peak Voltage since the last start was initiated. The voltage is displayed 
as a percentage of the rated capacity of the G7.
PG Speed — Displays the PG Speed.
Direction — Displays the Direction command (forward/reverse).