Toshiba H9 Manual De Usuario

Descargar
Página de 289
250
H9 ASD Installation and Operation Manual
Trips/Faults
Trip is a H9 ASD response to a Fault (though, Fault and Trip are sometimes used interchangeably). A 
Trip is a safety feature that disables the ASD system in the event that a subsystem of the ASD is 
malfunctioning or a parameter setting has been exceeded.
Listed in 
 are the Faults that may result in a Trip and the possible causes. When a Trip is 
incurred the system displays the Fault screen. The Fault screen identifies the active Fault.
A more user-friendly indication of the active Fault will be displayed at the LCD screen.
Table 14
LED Display
LCD Display
Possible Causes
E
Emergency Off
• Emergency Off command received via EOI or remotely.
E-10
Sink/Source Setting 
Error
• Improperly positioned Sink/Source jumper on the Terminal board or on an 
option device (see J100 at the Terminal PCB of the ASD).
• Sink/Source configuration is incorrect.
E-11
Brake Sequence 
Response Error
 is set to a non-zero value.
• Braking sequence discrete input and output terminals are not setup properly.
E-12
Encoder Signal-Loss 
Error
• ASD is configured to receive a signal from a shaft-mounted encoder and no 
signal is being received while running.
• Disconnection at the Encoder circuit.
• Motor is stopped and is generating torque via torque limit control.
• ASD is not configured properly.
E-13
Over Speed
• Result of a motor speed that is greater than the commanded speed when 
using an encoder for speed control.
• Improper encoder connection or setup information.
• Defective encoder.
E-17
Key Failure
• Same key input for 20 seconds or more.
E-18
Terminal Input Error
• V/I signal loss.
• Terminal Board failure.
• P24 overcurrent condition.
 setting is too high.
E-19
CPU Communication 
Error
• CPU data Transmit/Receive error.
E-20
V/f Control Error
• Torque processing error.
• Make service call.
E-21
CPU Processing 
Error
• Software processed incorrectly.
• Make service call.
E-22
Logic Input Voltage 
Error
• Incorrect voltage applied to the discrete input terminals.
E-23
Optional Expansion 
Input Terminal Board 
1 Error
• Optional Expansion Input Terminal Board 1 is defective.