H9 ASD Installation and Operation Manual
73
UP/DOWN Frequency
Pulse Input (option)
Pulse Input (motor CPU)
Binary/BCD Input (option)
Display Unit
This parameter sets the unit of measurement for current and voltage values displayed on the EOI.
Wizard: Finish
This is the final screen of the Startup Wizard. The basic parameters of the ASD have been set. Click 
Finish to return to the 
 mode. Additional application-specific programming may be required.
Operation (Local)
Note:
See the section titled 
 for information on Remote operation.
To turn the motor on perform the following:
1.
Connect the CC terminal to the ST terminal.
2.
Press the Mode key until the Frequency 
Command
 screen is displayed.
3.
Press the Local|Remote key to enter the Local 
mode (green Local LED illuminates).
4.
Turn the Rotary Encoder clockwise until the 
desired Frequency Command value is 
displayed in the SET field of the LCD screen.
5.
Press the Run key and the motor runs at the 
Frequency Command value.
Note:
The speed of the motor may be changed while the motor is running by using the Rotary 
Encoder
 to change the Frequency Command value.
6.
Press the Stop|Reset key to stop the motor.
Frequency Command Screen