NEC NDA-30115-001 Manual De Usuario
NDA-30115 Revision 1.0
Page 51
Property Management System - Communication Interface
Message Formats
•
Key -- Old room key status:
•
0 -- Key is in the key rack.
•
1 -- Key is not in the key rack.
•
New Extension -- New extension number. If the extension number is less than
six digits, left justify the number and fill the remaining bytes with space (20H)
characters.
six digits, left justify the number and fill the remaining bytes with space (20H)
characters.
•
Room Status 2 -- Room status of the new room. This flag is used in conjunction
with the cleaning status flag to determine the status of the room.
with the cleaning status flag to determine the status of the room.
•
Cleaning Status 2 -- Cleaning status of the new room. The possible
combinations with room status are listed below:
combinations with room status are listed below:
•
Key -- New room key status:
•
0 -- Key is in the key rack.
•
1 -- Key is not in the key rack.
Provisional Check
In
In
Figure 4-22 Provisional Check In
The only message field is the extension number that has been provisionally
checked in. If the extension number is less than six digits, left justify the number
and fill the remaining bytes with space (20H) characters. The room status is set to
“Stay” (Room Status = ‘1’, Cleaning Status = ‘0’) and Room Cut-Off is cancelled.
checked in. If the extension number is less than six digits, left justify the number
and fill the remaining bytes with space (20H) characters. The room status is set to
“Stay” (Room Status = ‘1’, Cleaning Status = ‘0’) and Room Cut-Off is cancelled.
Room
1
1
1
Clean
0
1
1
Status of the Room
Stay (Occupied)
Stay, Cleaning in progress
Stay, Cleaning in progress
1
1
1
2
3
3
Stay, Cleaning ended
Stay, Inspected
Stay, Inspected
‘5’ ‘6’
‘1’
‘1’
Extension
0
1
2
3
4
6
8
9
15
16
STX
SA
UA
EI
FTC
MSC
FC
6
02H ‘1’
‘!’
‘L’
03H xx
ETX BCC
‘7’