Nortel Networks Option 11C Mini Manual De Usuario

Descargar
Página de 334
 Appendix B – Changing preprogrammed data
Page 329 of 332
Option 11C Mini
Planning and Installation Guide
Creating model trunks and changing route access codes
If you need a trunk that is different from the default models provided in 
Option 11C Mini software, use Overlay 14 to design a model. Change route 
access codes using the administration telephone.
If you require additional help when creating model telephones and trunks, 
refer to the X11 Administration Input/Output Guide.
Creating model trunks
To create a new model trunk, load LD 14 and enter the following commands 
on the TTY:
LD 14
REQ NEW
TYPE aaa M “aaa” = the type of trunk that you are 
 creating (TIE, COT, WATS, and so on).
MODL YYY “YYY” = the model number of the trunk that you are creating 
(between 1 - 127)
XTRK   XUT, XEM, XCOT, This prompt only appears when you 
    XDID define the first model in a group. Each 
group contains 16 consecutive model
definitions. (Refer to the group limits
listed below.) When the first model in a 
group is defined, the remaining model 
numbers in the group(s) are taken to 
be of the same type.
Group limits are as follows:
1-15, 16-31, 32-47, 48-63, 64-79. 80-95, 96-111, 112-127.
Examples:
If, for example, you define a model trunk as XUT, with a model number of 
12, all models in the group 1-15 will automatically be XUT models. If you 
define another model trunk as an XEM, with a model number of 33, all 
models in the group 32-47 will automatically be XEM models.
Note: When you create trunk models, you are not prompted for the trunk 
route or member number. This information is defined using the 
administration telephone to program the XUT or XEM circuit card.
For more information about LD 14, refer to the X11 Administration 
Input/Output Guide
.