Finisar Surveyor Manual De Usuario

Descargar
Página de 454
12-4
Surveyor 
User’s Guide
Table 12-3 contains an alphabetical list, with descriptions, of Surveyor’s Token 
Ring error counters.
Table 12-3. Alphabetical List and Descriptions of Token Ring Error Counters
Token Ring Counter
Description
Abort Delimiter
Records events where a reporting Ring Station encounters recover-
able internal errors, forcing it to transmit an Abort Delimiter frame.
AC Error
Records events where the reporting Ring Station’s nearest active 
upstream neighbor could not set the address recognized bits or frame 
copied bits in the newly transmitted frame after copying the bits on the 
last frame received.
Burst Error
Records events where the reporting Ring Station encounters signal 
transition or signal error on the Token Ring physical medium 
Frame Copy
Records when a reporting Ring Station copies a frame containing the 
Ring Station’s own (duplicate) address.
Frequency
Records events where the reporting Ring Station attempts to receive a 
frame containing an improper ring-clock frequency.
Internal Error
Records events where the reporting Ring Station encounters a recov-
erable internal error.
Line Error
Records events where the reporting Ring Station’s checksum process 
detects an error in a received data frame or token that the Ring Station 
transmitted.
Lost Frame
Records events where a reporting Ring Station generates a frame to a 
specific address and does not receive the returned frame.
Token Error
Records events where the Token Ring Active Monitor does not detect 
a ring token.