Table 4-7. Strip Chart Display Timers
The values for polling timers must be between 1 and 214783647 seconds. The 
values for the display timers must be between 1 and 214783647 seconds. The 
strip chart display timers must be in multiples of the MAC Layer Counter timer. 
The default settings, in seconds, are shown in Table 4-8:
Table 4-6. Remote Polling Timers
Polling Timers
Description
MAC Layer Counters
Sets the interval for polling devices for MAC layer counters.
Protocol Distribution
Sets the interval for polling devices for the protocol distribution information.
Host Table 
Sets the interval for polling devices for MAC layer host table information.
Matrix Views
Sets the interval for polling devices for information on MAC, network, and 
application layer conversations.
Expert Data
Sets the interval for polling devices for expert data.
Remote Name Table
Sets the polling interval for refreshing the local copy of the name table for 
a remote resource.
Display Timers
Description
Strip Chart Display 
Timer, Local 
Sets the time between refreshing counters in strip charts for resources in 
the local PC. This display timer is available for strip charts only.
Strip Chart Display 
Timer, Remote
Sets the time between refreshing counters in strip charts for resources in 
remote hosts. This display timer is available for strip charts only.
Table 4-8. Default Display Timer Settings
Display Timer
Default Value
MAC Layer Counters 
 3
Protocol Distribution
 5
Host Table Views
 7
Matrix Views
10
Expert Data View
15
Remote Name Table
300
Strip Chart, Local
1
Strip Chart, Remote