Delta Electronics PG-03 Manual De Usuario

Descargar
Página de 4
3
 
PG-03 Terminal Descriptions
 
Terminals 
 
Terminal Symbols 
Descriptions 
+12V 
Power Supply of the Encoder: +12V   
Output Voltage: +12V
±5% 200mA 
0V 
Common point for the power supply and the signal 
 
Encoder signal input (select the output type of the Encoder from FSW2)
Both single-phase input and two-phase input available 
Maximum: 500KP/Sec 
A/O, B/O 
The Encoder signal output 
Maximum: DC24V 50mA 
 
Common point for signal grounding 
 
Wiring Notes 
1.  Please use a shield cable to prevent interference. Do not run control wire parallel to any high 
voltage AC power line (220 V and up). 
2.  Connect shielded wire to     E only.  
3.  Recommended wire size 0.21 to 0.81mm
(AWG24 to AWG18). 
4. Wire 
length: 
The Output Types of the 
Encoder 
Maximum Wire 
Length 
Wire Gauge 
Output Voltage 
50m 
Open Collector 
50m 
Line Driver 
300m 
Complementary 70m 
1.25mm
(AWG16) or above