Delta Electronics none Manual De Usuario

Descargar
Página de 355
Chapter 6  Control Modes of Operation|ASDA-AB Series
 
6-38  
 
Revision March 2008, Doc. Name: 2007PDD23000011
 
For example: 
If we use 400W servo drive, the time of repeat operation cycle is T = 0.4 sec, max. motor speed is 
3000r/min, the load inertia = 7 ×  motor inertia, then the necessary the power of regenerative resistor = 2 
x ( (7+1) × 1.68 - 8) / 0.4 = 27.2W. If the calculation result is smaller than regenerative power, we 
recommend the users to use the built-in 60W regenerative resistor. Usually the built-in regenerative 
resistor provided by ASDA-AB series can meet the requirement of general application when the external 
load inertia is not excessive.  
The users can see when the capacity of regenerative resistor is too small, the accumulated power will 
be larger and the temperature will also increase. The fault, ALE05 may occur if the temperature is over 
high. The following figure shows the actual operation of regenerative resistor. 
 
(2)  With Load 
When there is an external load torque, servo motor is in reverse rotation when external load greater 
than motor torque. Servo motor is usually in forward rotation and the motor torque output direction is the 
same as the rotation direction. However, there is still some special condition. If the motor output torque 
is in the reverse direction of rotation, the servo motor is also in the reverse direction of rotation. The 
external power is input into the servo drive through servo motor. The Figure 6.21 below is an example. 
The users can see the motor is in forward rotation at constant speed when a sudden external load 
torque change and great power is transmitted to regenerative resistor rapidly. 
Motor Rotation Speed
External Load Torque
Motor Output Torque
Reverse
Rotation
Reverse
Rotation
Forward
Rotation
Forward
Rotation
 
 
External load torque in reverse direction: TL x Wr      TL : External load torque 
For the safety, we strongly recommend the users should select the proper resistance value according to 
the load.