Delta Electronics VFD007S23A Manual De Usuario

Descargar
Página de 186
 
 Chapter 1 Introduction|VFD-S Series 
Revision August 2006, SE08, SW V2.61 
1-3
1.3 Installation Steps 
CASE
HEAT SINK
COVER
KNOB
 
 
SCREW
DIVISION 
PLATE
 
Installation Steps 
1. 
Remove front cover screw and open.  
2. 
Remove Division Plate. If using optional 
conduit bracket, please refer to next 
page. 
3. 
Connect AC Input Power and motor leads. 
Never connect the AC drive output 
terminals U/T1, V/T2, W/T3 to main AC 
Input power.
 
4. 
Reinstall Division Plate.
 
CONDUIT
BRACKET
SCREW
SCREW
 
For Optional Conduit Bracket: 
Make sure to fasten both screws on conduit 
bracket as shown in the drawing for safety 
grounding purpose.  Bring all the wires out 
through the conduit bracket. 
Screw Torque: 5 to 6 kgf-cm (4.3 to 5.2 in-lbf)