SFP timing parameters for SFP management 
Parameter 
Symbol 
Min. 
Max. 
Unit 
Note 
TX_DISABLE Assert time 
t_off 
 
10 
µsec 1 
TX_DISABLE Negate time 
t_on 
 
msec 
Time to initialize, including 
reset of TX_FAULT 
t_init  
300 
msec 
TX Fault Assert Time 
t_fault 
 
100 
µsec 
TX_DISABLE to reset 
t_rest 
10 
 
µsec 5 
LOS Assert Time 
t_loss_on 
 
100 
µsec 
LOS Deassert Time 
t_loss_off 
 
100 
µsec 7 
Serial ID Clock Rate 
f_serial_clock 
 
100 
kHz 
 
Notes: 
1) 
Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal
 
2) 
Time from falling edge of TX_DISABLE to when the modulated optical output rises above 90% of 
nominal
 
3) 
From power on or negation of TX_Fault using TX Disable
 
4) 
Time from fault to TX fault on.
 
5) 
Time TX Disable must be held high to reset TX_Fault
 
6)  Time from LOS state to Rx LOS assert 
7)  Time from non-LOS state to Rx LOS deassert