Delta Electronics VFD-VE Series Manual De Usuario

Descargar
Página de 291
Appendix B  Accessories
B-18 
Revision August 2008, 03VE, SW V2.04
 
B.8 PG Card (for Encoder) 
B.8.1 EMV-PG01X 
AB2:
PG2 signal
mode switch
ABZ1:
PG1 signal
mode switch
PG1
Pulse feedback  
PG2
Pulse input
PS1:
5/12V switch
 
 
1. Terminals descriptions 
Terminal Symbols 
Descriptions 
VP 
Power source of EMV-PG01X (use PS1 to switch 12V/5V)  
Output Voltage: +5V/+12V
±5% 200mA 
DCM 
Power source and input signal common 
A1, 
B1, 
Z1, 
A1
B1
Z1
 
Input signal. Input type is selected by ABZ1. It can be 1-phase or 2-
phase input. Maximum 300kP/sec 
A2, 
B2, 
A2
B2
 
Input signal. Input type is selected by AB2. It can be 1-phase or 2-
phase input. Maximum 300kP/sec 
 
Grounding 
 
2. Wiring Notes 
a. 
Please use a shielded cable to prevent interference. Do not run control wires 
parallel to any high voltage AC power line (200 V and above).  
b. 
Recommended wire size 0.21 to 0.81mm
(AWG24 to AWG18). 
3. Wire length (wire length and signal frequency are in inverse proportion)