Mackie D8B v5.1 Manual De Usuario

Descargar
Página de 198
D8B Manual • Chapter 4 • page  121
TDIF Hookup to HDR24/96 (DIO•8)
Cables & Hardware
(3) DIO8 cards for HDR24/96
(3) DIO8 cards for D8B
(1) Clock I/O card for D8B
(3) TDIF cables
(1) 75 
Ω BNC word clock cable
Hookup
1.  Connect the three TDIF cables
between the corresponding TDIF jacks
on the HDR24/96 and D8B.
2.  When TDIF is used, the D8B must
have a Clock I/O card installed. To
make the D8B the clock master,
connect its Word Clock Out (not
DIO8 Sync out) to the HDR24/96
Word Clock In. To make the HDR24/96
the clock master, connect its Word
Clock Out to the D8B Word Clock In.
HDR24/96 Settings
1.  Set the Tape Input format for each
DIO8 card to TDIF, and the Tape
Output format to TDIF.
2.  If the HDR24/96 is the clock master,
set the Sample Clock to Internal; if it
is a clock slave, set it to Word Clock
and depress the 75 
Ω termination
switch on the Sync card.
3.  Set the Sample Rate to 44.1kHz or
48kHz according to your preference.
TDIF Hookup with DIO
8
Digital 8
Bus
APOGEE
SYNC
APOGEE
Word Clock Out
Word Clock
In
Word
Clock Out
(HDR24/96
as Master)
Word
Clock
Out
(D8B as
Master)
TDIF Connection
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
Word
Clock In
TDIF Cables
(DB25)
DIO•8 Cards
Word
Clock Out
Apogee
Clock I/O
Card
TDIF Connection
S
C
NOT
WARNING
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
APOGEE
DIGITAL I/O
SYNC
IN
OUT
TDIF
ADAT OPTICAL
HDR
Sync
Card
Word
Clock In
HDR 24/96
DIO•8 Cards
Word
Clock Out
Use
one
only
Depress the
Termination
button if the
HDR24/96 is
set to Slave