RAD Data comm RIC-155 Manual De Usuario

Descargar
Página de 90
RIC-155 Installation and Operation Manual 
Chapter 4  Configuration 
 
Configuring RIC-155 for Management 
4-5 
RIC-155 
 
Manager List 
 Manager ID   IP address    Trap Mask 
    1.        0.0.0.0       NO 
    2.        0.0.0.0       NO 
    3.        0.0.0.0       NO 
    4.        0.0.0.0       NO 
    5.        0.0.0.0       YES 
 
 
ESC-prev.menu; !-main menu; &-exit; ?-help 
Figure 4-6.  Manager List Menu 
Controlling the Management Access 
You can enable or disable access to the RIC-155 management system via SNMP, 
Telnet or Web-based applications. By disabling SNMP, Telnet or Web, you prevent 
unauthorized access to the system when security of the RIC-155 IP address has been 
compromised. When SNMP, Telnet and Web access is disabled, RIC-155 can be 
managed via an ASCII terminal only. In addition, you can enable or disable an 
inband management (via uplink or DATA port) or out-of-band (via MNG port).  
 
To define the management access method: 
1.  Follow the path: Configuration > System Configuration > Management > 
Management Access
The Management Access menu appears. 
2.  From the Management Access menu, select TELNET Access to configure 
Telnet access, select SNMP Access to configure SNMP access, or select WEB 
Access
 to configure Web access. 
A TELNET Access, SNMP Access or WEB Access menu appears 
(see 
 
During a Telnet session, Telnet Access is masked. 
During a SNMP session, SNMP Access is masked. 
During a Web session, Web Access is masked. 
 
3.  From the TELNET Access, SNMP Access or WEB Access menu, select ENABLE 
to allow selected management type, DISABLE to restrict it, or Managers Only 
to allow access only for the management stations defined in the Manager List 
menu (see 
4.  If the Web management (ConfiguRAD) is enabled, you can select WEB Trace 
Refresh
 from the Management Access menu, and define refresh rate of the 
Trace pane in seconds (1255). 
Note