RAD Data comm RIC-155 Manual De Usuario

Descargar
Página de 90
RIC-155 Installation and Operation Manual 
Appendix B  Traffic Separation 
 
Configuring for a Typical Application 
B-7 
The units are configured as follows: 
•  Local RIC-155: 
 
Forwarding – Filter Tagged 
 
Port Management Access – MNG Only 
 
Host Tagging – Untagged 
 
Management and data ports – Tag stripping is enabled 
 
uplink port – Stack. 
•  Remote RIC-155: 
 
Forwarding – Filter Tagged 
 
Port Management Access – None 
 
Host Tagging – Untagged 
 
Management and data ports – Tag stripping is enabled 
 
uplink port – Stack. 
 
When the forwarding mode is set to Filter Tagged or port access mode is set to 
MNG Only, the following parameters are enabled automatically: 
•  Tag stripping at the management and data ports  
•  Stacking at the uplink port. 
 
MNG 1
1
1
1
Local RIC-155
Remote RIC-155
2
2
2
2
Host
Host
Uplink
Uplink
Data
Management
Station
LAN
LAN
Data
 
Figure B-9.  Managing RIC-155 via MNG Port 
Managing RIC-155 via Data Port 
 shows two RIC-155 units managed via data port. In this application the 
management and data frames are tagged by an external switch and sent to the 
data port. The Data port is configured to leave the incoming frames unchanged 
(tag stripping is disabled). At the egress from the data port, the management frames 
are forwarded to the host and uplink ports, and the data frames are sent to the 
uplink port only. The host port adds VID 1 to the management frames to ensure 
that they reach the management station when they are sent back. At the egress 
from the uplink port, no tags are added to the frames, because they arrive tagged.  
When the frames enter the remote uplink port their tags are checked against the 
remote VTU table and forwarded according to their tags: 1 to the host port and 2 
to the data port. The host port strips the VLAN tag of the management frames and 
forwards them to the CPU. 
Note