Status Indicators and Alarm Relay 
4-1 
Chapter 4 
Testing and Diagnostics 
This chapter describes the FOM-E1/T1 diagnostics functions, which include: 
•  Front panel LED indicators 
•  Alarm relay 
•  Diagnostic loopbacks. 
In addition, this chapter provides some tips on troubleshooting and frequently 
asked questions. 
4.1  Status Indicators and Alarm Relay 
Front Panel LEDs 
The status of FOM-E1/T1 is indicated by the front panel LED indicators. For 
description of LED indicators and their functions, refer to 
Alarm Relay 
FOM-E1/T1 supports dry contact alarm relay via reserved pins of the DB-15 female 
connector. The following fault conditions trigger relay of the major and minor 
alarms: 
•  Major alarms are initiated when E1/T1 electrical input becomes lower than 
G.703 electrical levels, or bit error rate at the fiber optic interface is 10
-6
 or 
worse.  
•  Minor alarms occur when an Alarm Indication Signal is received at the E1/T1 
electrical or fiber optic interfaces.  
 lists the DB-15 connector pins used for the alarm relay. 
Table 4-1.  DB-15 Connector, Alarm Relay Pins 
Pin Contact 
Alarm 
Type 
7, 8 
Normally Closed 
15, 8 
Normally Open 
Minor 
5, 6 
Normally Closed 
13, 6 
Normally Open 