Graco 24B596 Manual De Usuario

Descargar
Página de 36
Troubleshooting
313855H
33
Troubleshooting
Program Settings
Description
Problem
Solution
Timer fails to activate solenoid
No power supplied to solenoid
Power light off: Timer is not receiving 
power. Verify connections and verify 
power supply.
Power light on: Verify solenoid con-
nections
Solenoid faulty
Replace solenoid
Timer faulty
Replace timer
Low level or other alarm
Refill reservoir
Pressure switch fails to shut down 
system
Pressure switch incorrectly wired
Verify proper connections
Pressure switch faulty
Replace pressure switch
Timer faulty
Replace timer
Description
Modes of Operation 
Maximum / Minimum and Additional Comments
TIMER Setup, page 18
HH:MM:SS (00:00:01 - 99:59:59)
PRESSURE Setup, page 19
HH:MM:SS (00:00:01 - 99:59:59)
CYCLE END Setup, page 19
HH:MM:SS (00:00:01 - 99:59:59)
CYCLE MODE Selection, page 20
Cycles = 01 - 99
PUMP ON Setup, page 18
Time, Pressure or Cycles
Pump ON Time: HH:MM:SS (00:00:01 - 99:59:59)
Cycles: 01 - 99 (only used when mode of operation = cycles)
PUMP OFF Setup, page 20
Time, Count or Both
Pump OFF Time: HH:MM:SS. (00:00:01 - 99:59:59)
Count: 01 - 9999
POWER UP Setup, page 22
MM:SS (00:01 - 59:59)
PULSED Output (pump), page 24
Maximum Time OFF and Time ON: SS (01-99) 
PIN Number Setup, page 25
ON / OFF
0000 - 9999
QUICK CYCLE SCREEN Setup, page 26
Cycles = 01 - 99
Time ON and Time OFF: SS (01-99)
Execute: YES / NO
PRELUBE on Power Up, page 30
YES / NO
Delay: YES / NO
TIME: MM:SS (00:01 - 59:59)