Run Mode 
30
313855H
Prelube Power Up 
If Prelube is enabled (page 22), the programmed pre-
lube sequence occurs. 
If no Prelube sequence has been selected, the lube 
cycle that was in progress at power down is resumed.
Pump On Ended with Time
If the Pump On sequence has been programmed to be 
ended by TIME:
The GLC 4400 pump output relay activates (J7-3) 
and will stay on until the time expires. (see Setup 
Menus, Pump On, page 18).
The Pump On LED (A) remains on during this time.
The Pump On (C) icon displays.
The Timer icon (D) displays and indicates the Timer 
Mode.
Pump On Ended with Pressure
If the Pump On sequence has been programmed to end 
by a pressure switch:
The GLC 4400 pump output relay activates (J7-3) 
and will stay on until a switch closure is received 
(J6-3) (see Setup Menus, Pump On, page 19).
The Pump On LED (A) remains on during this time.
The Pump On (C) icon displays.
The Cycle LED (B) illuminates and Pressure Mode 
icon (D) displays to indicate the pressure switch.
If the pressure switch closure is not received before 
time expires, an alarm occurs.
NOTE: If Pump On is ended by a pressure switch and 
no Power Up delay is selected, when power to the GLC 
4400 is turned on, the GLC 4400 starts at the beginning 
of the Pump On time instead of resuming the Pump On 
time where it left off.
F
IG
. 55
F
IG
. 56
A
D
C
F
IG
. 57
A
B
C
D