2. Target status LEDs
The target status LEDs indicate the status of the target MCU's operation and the target board's
power supply, etc. Table 2.2 lists the definitions of the target status LEDs.
Take note of the fact that the target status LEDs cannot show the MCU status properly after the
emulator is powered on until the emulator debugger gets started.
Table 2.2 Definitions of the target status LEDs
Name
ON/OFF
OFF
ON
OFF
ON
OFF
Meaning
Power is not supplied to the target board.
Power is supplied to the target board.
Target program has been halted.
Target program is being executed.
Target MCU is not being reset from an external pin.
Target MCU is being reset from an external pin.
When connected by JTAG, it is not turned on by inserting a buffer into
the RST signal of the SDI MCU control signal on the target board.
ON
POWER
RUN
RESET