Renesas HS7343KCU01HE Manual De Usuario

Descargar
Página de 57
 
 
1.2 
Connecting the Emulator with the User System 
To connect the E10A-USB emulator (hereinafter referred to as the emulator), the H-UDI port 
connector must be installed on the user system to connect the user system interface cable.  When 
designing the user system, refer to the recommended circuit between the H-UDI port connector 
and the MPU.  In addition, read the E10A-USB emulator user's manual and hardware manual for 
the related device. 
Table 1.2 shows the type number of the emulator, the corresponding connector type, and the use of 
AUD function. 
Table 1.2   Type Number, AUD Function, and Connector Type 
Type Number 
Connector 
AUD Function 
HS0005KCU02H 36-pin 
connector 
Available 
HS0005KCU01H, HS0005KCU02H 
14-pin connector 
Not available 
 
The H-UDI port connector has the 36-pin and 14-pin types as described below.  Use them 
according to the purpose of the usage. 
1.  36-pin type (with AUD function) 
The AUD trace function is supported.  A large amount of trace information can be acquired in 
realtime.  The window trace function is also supported for acquiring memory access in the 
specified range (memory access address or memory access data) by tracing. 
2.  14-pin type (without AUD function) 
The AUD trace function cannot be used because only the H-UDI function is supported.  Since 
the 14-pin type connector is smaller than the 36-pin type (1/2.5), the area where the connector 
is installed on the user system can be reduced.