2.11.3 Using the Oscillator Circuit on the User System 
To operate this product with an external clock, construct the oscillator circuit as shown in Figure 2.22 in the user system and 
input the oscillator output at 50% duty (within the operating range of the evaluation MCU) into pin X
IN
. And pin X
OUT
 should 
be open. Choose "External" in the emulator debugger to use this clock. 
 
 
 
Figure 2.22 External oscillator circuit 
 
Make note that in the oscillator circuit shown in Figure 2.23 where a resonator is connected between pins X
IN
 and X
OUT
oscillation does not occur because a converter board and other devices are used between the evaluation MCU and the user 
system. It is same for sub-clock oscillator circuits (X
CIN
 and X
COUT
). 
 
 
 
Figure 2.23 Circuit in which oscillation does not occur 
 
2.11.4 Using the Internal Generator Circuit 
The dedicated circuit in the PC7501 can generate any arbitrary frequency specified by the emulator debugger, and it can be 
supplied as a main clock. It does not depend on either the oscillator circuit board in the PC7501 or the oscillator circuit on the 
user system. If you want to debug programs without the user system or change a frequency temporarily, you can check its 
operation before purchasing an oscillator. If you want to use the internal generator circuit in the PC7501 as a main clock, 
choose "Generate" in the emulator debugger and specify a frequency you like to use this clock. 
Although you can change a frequency between 1.0 and 99.9 MHz by 0.1 MHz for the PC7501, do not specify a value 
exceeding the maximum input frequency of the X
IN
 of an MCU. 
 
IMPORTANT 
Notes on Using the Internal Generator Circuit: 
 
z
 The internal generator circuit is equipped for temporary debugging purposes. Temperature characteristics of 
frequencies are not guaranteed. 
z
 Be sure to evaluate your system with an oscillator or oscillator module whose frequency is same as that of the 
internal oscillator circuit (internal clock) for final evaluation purposes.