3. Usage (How to Use the Emulator Debugger) 
REJ10J0519-0200  Rev.2.00  Oct. 16, 2006 
 
Page 64 of 104 
 
 
(3) When DATA ACCESS is selected 
 
1. Window for setting the address 
Setting the address 
Set in the Address tab. 
You can set eight conditions, e.g., a specified address, a specified 
address range, etc. 
After finishing the setting the address, set the data. 
 
 
 
 
 
2. Window for setting data 
Setting data 
Set in the Data tab. 
You can set eight conditions, e.g., a specified data, a specified data 
range, etc. 
 
 
 
 
 
Setting the access condition 
You can set three conditions, e.g., read, write, and read/write. When 