(2) MCU Setting Dialog Box Does Not Appear at Emulator Debugger Startup 
 
Table 5.2 Checkpoints of errors at debugger startup   
Error Checkpoint 
ERROR 16005: 
Communication error occurred. 
Data was not sent to the target. 
Check all emulator debugger settings, interface cable settings and 
switches on the rear of the PC7501 match. 
See the user's manuals of PC7501 and emulator debugger. 
 
ERROR 16207: 
User system cannot be properly built. 
(1) Download the proper firmware. 
 
See "2.7 Downloading Firmware" (page 28). 
(2) Recheck the connection between the PC7501 and this product. 
 
See "2.4 Connecting the PC7501" (page 24). 
 
ERROR 16211: 
PD30F’s version is not the same version as the 
firmware in the target. 
Download the proper firmware. 
See "2.7 Downloading Firmware" (page 28). 
 
ERROR 16614: 
Target MCU is in the reset state. 
Reset the user system. 
(1) Check that the reset pin of the user system is at “H” level. 
(2) Check the reset pin of the user system has changed from "L" to "H" 
level. 
 
ERROR 16615: 
Target MCU cannot be reset. 
Reset the user system. 
(1) Check that the NMI# pin is at “H” level. 
(2) In memory expansion mode or microprocessor mode, check pins 
RDY# and HOLD# are at “H” level. 
(3) If the reset circuit of the user system has a watchdog timer, disable 
the watchdog timer. 
(4) Check that power is properly supplied to the user system and that the 
user system is properly grounded. 
 
ERROR 16616: 
Target is in "HOLD" state. 
(1) In memory expansion mode or microprocessor mode, check pins 
RDY# and HOLD# at “H” level. 
(2) The MCU is either in stop mode or wait mode. Either reset the MCU 
or cancel the mode with an interrupt. 
 
See MCU specifications. 
 
ERROR 16617: 
Target clock is stopped. 
When the clock is supplied from an external oscillator, check that the 
oscillator circuit in the user system is oscillating properly. 
 
ERROR 16618: 
Target MCU is not receiving power. 
Check that power is properly supplied to the user system and that the 
user system is properly grounded.