HP (Hewlett-Packard) PCI-9111DG/HR Manual De Usuario

Descargar
Página de 83
46 
 C/C++ Library 
5.17  _9111_AD_Set_Range  
@ Description 
This function is used to set the A/D range by means of writing data to the 
gain control register.  The initial value of gain is '1' which is the default 
setting by the PCI-9111 hardware. The relationship between gain and 
input voltage ranges in the following table: 
Input Range (V) 
Gain 
Gain Code 
±
10 V 
X 1 
AD_B_10_V 
±
5 V 
X 2 
AD_B_5_V 
±
2.5 V 
X 4 
AD_B_2_5_V 
±
1.25 V 
X 8 
AD_B_1_25_V 
±
0.625V 
X 16 
AD_B_0_625_V 
@ Syntax 
C/C++ (DOS) 
U16 _9111_AD_Set_Range (U16 cardNo, U16 ADRange) 
C/C++ (Windows 95) 
U16 W_9111_AD_Set_Range (U16 cardNo, U16 ADRange) 
Visual Basic (Windows 95) 
W_9111_AD_Set_Range (ByVal cardNo As Integer, ByVal ADRange As 
Integer) As Integer 
@ Argument  
cardNo: 
The card number of PCI-9111 card initialized 
ADRange:  The programmable gain of A/D conversion, the possible 
values are: AD_B_10_V, AD_B_5_V, AD_B_2_5_V, 
AD_B_1_25_V, AD_B_0_625_V. 
@ Return Code 
ERR_NoError