C/C++ Library 
61 
function _9111_AD_FFHF_INT_Status().  While all the specified blocks 
of data are acquired, the interrupt status will be changed to 
“AD_FFHF_BLOCK_FULL”.  The function can perform on single A/D 
channel (autoscan is disable) or multiple A/D channels (autoscan is 
enable) with fixed analog input range. 
@ Syntax  
C/C++ (DOS) 
U16 _9111_AD_FFHF_INT_Start (U16  cardNo,  U16 auto_scan,  U16 
ad_ch_no, U16 ad_gain, U16 blockNo, I16 far *ad_buffer, U16 c1, 
U16 c2) 
C/C++ (Windows 95) 
U16 W_9111_AD_FFHF_INT_Start (U16 cardNo, U16 auto_scan, U16 
ad_ch_no, U16 ad_gain, U16 blockNo, I16 far *ad_buffer, U16 c1, 
U16 c2) 
Visual Basic (Windows 95) 
W_9111_AD_FFHF_INT_Start (ByVal cardNo As Integer, ByVal 
auto_scan As Integer, ByVal ad_ch_no As Integer, ByVal ad_gain 
As Integer,  ByVal blockNo As Integer, ad_buffer As Integer, 
ByVal c1 As Integer, ByVal c2 As Integer) As Integer 
@ Argument  
cardNo: 
the card number of PCI-9111 card initialized. 
auto_scan:  0:  autoscan is disabled. 
 
1:  autoscan is enabled. 
ad_ch_no: 
A/D channel number. 
If the auto_scan is set as enable, the selection 
sequence of A/D channel is: 0, 1, 2, 3, ... , [ad_ch_no], 0, 
1, 2, 3, ... , [ad_ch_no], ... . 
If the auto_scan is set as disable, only the data input 
from [ad_ch_no] is converted.  
ad_gain: 
A/D analog input range, the possible values are:  
 
 
AD_B_10_V, AD_B_5_V, AD_B_2_5_V, 
AD_B_1_25_V, AD_B_0_625_V, 
blockNo: 
the number of blocks for performing A/D convertion, 
one block of A/D conversion is 512. 
ad_buffer: 
the start address of the memory buffer to store the AD 
data, the buffer size must large than the number of AD 
conversion (blockNo*512). 
c1: 
the frequency devider of Timer#1. 
c2: 
the frequency devider of Timer#2. 
@ Return Code  
ERR_InvalidADChannel  
ERR_AD_InvalidGain 
ERR_InvalidTimerValue  
ERR_NoError