STARLINE 3 
 
SG2-DRT-3X Installation Sheet 
Table 1 provides information on the user-related features of the SG2-DRT-3X. 
Key Feature 
Description 
OPTICAL
POWER
(1 V/mW)
 
This test point enables monitoring of the optical output level of the module. 
The nominal scale factor is 1.0 V/mW (6.3 V equates to 8 dBm). The optical 
power test point does not track changes in optical power due to the laser 
tracking error
ALARM
F
A
U
L
T
O
N
 
A red (
FAULT
) LED indicates that the laser output power is below normal 
limits. 
A green LED (
ON
) indicates the transmitter is enabled. 
Because the laser output requires a short period of time to stabilize, it is 
normal for neither LED to illuminate for approximately 10 seconds. The 
module must be enabled for the fault indicator to function
I
N
P
U
T
A
 
This MCX connector provides the SG2-DRT-3X with channel A RF input 
through a cable connection to the node lid board in an SG2440 or the E-pack 
in an SG2000. 
I
N
P
U
T
B
 
This MCX connector provides the SG2-DRT-3X with channel B RF input 
through a cable connection to the node lid board in an SG2440 or the E-pack 
in an SG2000. 
Channel C RF input is provided by direct connection of the node lid board 
with the D-type connector on the bottom of the SG2-DRT-3X. 
 
This SC/APC-type connector provides optical output from the SG2-DRT-3X. 
Figure 3 illustrates a side view of the SG2-DRT-3X and indicates the laser warning label. 
Figure 3  
SG2-DRT-3X side view and laser warning label 
INVISIBLE LASER RADIATION WHEN OPEN
PEAK POWER 10 mW
CLASS  LASER PRODUCT
I
CHAPTER 1 SUBCHAPTER J
THIS PRODUCT COMPLIES WITH 21CFR
DANGER