Multi-Tech Systems MT5634MSV Manual De Usuario

Descargar
Página de 114
4   AT Commands, S-Registers, and Result Codes
41
Command:
$D
n
DTR Dialing
Values:
n = 0 or 1
Default:
0
Description:
$D0
Disables DTR dialing.
$D1
Dials the number in memory location 0 when DTR goes high.
Command:
$EB
n Asynchronous Word Length
Values:
n = 0 or 1
Default:
0
Description:
$EB0 Enables 10-bit mode.
$EB1 Enables 11-bit mode.
Command: +ES=n Enable Synchronous Buffered Mode
Values:
n = 6
Default:
None
Description:
Allows an H.324 video application direct access to the synchro-
nous data channel. On underflow, the modem sends HDLC
flag idle (0x7E) to the remote modem.·This special error con-
trol mode is overridden by any of the following commands:
&F
&M&Q, or \N.
AT+ES=?
 shows the only allowed value.
AT+ES?
 shows the current value.
Command:
#S
x
Enter Setup Password
Values:
x= password (1–8 characters, case sensitive)
Default:
MTSMODEM
Description:
Enters the remote configuration setup password.
Command:
#S=
x Store Setup Password
Values:
x= password (1–8 characters, case sensitive)
Default:
MTSMODEM
Description:
Stores a new remote configuration setup password.
Command: +++AT<CR>   Escape Sequence
Values:
n/a
Description:
Puts the modem in command mode (and optionally issues a
command) while remaining online. Type +++AT and up to ten
command characters, then press ENTER. Used mostly to issue
the hang-up command: +++ATH<CR>.
Command: %%%AT<CR> Remote Configuration Escape Sequence
Values:
n/a
Description:
Initiates remote configuration mode while online with remote
modem. The remote configuration escape character (%) is de-
fined in register S13.