 1 System overview
8
Weight 
The table below lists the weight of individual components used in 
deployment of this system in third-party racks. 
Power consumption
The server power supply is rated for a maximum 220W DC output. 
Maximum input AC power consumption is approximately _____.
Using 110V AC power, a fully loaded system can consume up to 
2.80A
Using 220V AC power, a fully loaded system can consume up to 
1.40A
Deployment of ultra-dense 1U servers represent a significant power 
requirement. A simple formula to calculate server power requirements 
for an installation is:
(Number of servers) x (307W) = maximum power requirements for servers
Item
 Weight in Kg
Weight in lbs
Fully configured 
system
13 Kg
28.6 lbs
Rack mount kit
3.1 Kg
6.82 lbs
CPU and fan sink
0.35 Kg
0.77 lbs
Hard disk drive
1Kg
2.2 lbs
Power supply module
1.3 Kg
2.86 lbs
Floppy disk drive
0.16 Kg
0.35 lbs
CD-ROM drive
0.3 Kg
0.66 lbs
PCI card
0.04 ~ 0.4 Kg
0.09 ~ 0.88 lbs