ADC H2TU-C-231 Manual De Usuario

Descargar
Página de 74
LTPH-UM-1109-01, Issue 1
Monitoring System Activity and Performance
H2TU-C-231 List 2
January 9, 2002
35
Alarm History at the HDSL2 Interface
The HDSL2 Alarm History screens report alarms at the H2TU-C and the H2TU-R.
shows the H2TU-C
HDSL2 alarm history and
below describes the alarms that are reported at the H2TU-C-231 or H2TU-R.
Figure 23.
H2TU-C HDSL2 Alarm History Screen
Table 12.
HDSL2 Alarm Descriptions
Screen Alarm
Front-Panel Alarm Description
HDSL2 ALARMS at the H2TU-C and H2TU-R 
LOSW
LOSW
Loss of Sync Word—The HDSL2 loop has lost synchronization. 
MAL
xxx-MAL
Margin—The margin on the HDSL2 loop has dropped below the minimum threshold value 
set for the system. (xxx denotes either TUC or TUR.)
LA
xxx-LA
Loop Attenuation—The attenuation on the HDSL2 loop has exceeded the maximum value 
set for the HDSL2 loop attenuation threshold. (xxx denotes either TUC or TUR.)
HBER
xxx-HBER
Block Error Rate—The HDSL2 BER has exceeded the set threshold limits of 
10
-6
 or 10
- 7
. (xxx denotes either TUC or TUR.)
HDSL2 ALARMS at the H2TU-C only
SHORT
PWR FEED SHRT
Indicates a short between the Tip and Ring of the HDSL2 pair.
GND
PWR FEED GND
The HDSL2 loop is grounded.
OPEN
PWR FEED OPEN
Indicates a line power open condition.
Monitor
Performance
Event Log
Config
Inventory
Report
Rlogon
Help
H2TU-C HDSL2 Alarm History
-----------------------------------------------------------------------------
Alarm
First
Last
Status
Count
LOSW
OK
0
MAL
OK
0
LA
OK
0
HBER
09/01/01 00:37
09/01/01 00:45
OK
7
SHORT
OK
0
GND
OK
0
OPEN
OK
0
Press: C(l)ear Alarm History
------------------------------------------------------------------------------
Use <Space> to cycle through
Interface
:
H2TU-C HDSL2
choices and <Enter> to view
Statistics :
Alarm History
ID: xxxx--xxxx--xxxx--xxxx
09/01/2001 12:30:01
H2TU-C
System: Alarm