Chapter 3      Bringing Up the Cisco IOS XR Software on a Multishelf System
Bringing Up and Verifying the Non-DSC LCC
SUMMARY STEPS
1.
Apply power to the second LCC.
2.
show controllers fabric rack all detail
3.
show controllers fabric plane all detail
4.
show controllers fabric connectivity all detail
5.
On the external Catalyst switches, verify that the links are not unidirectional.
6.
exit
DETAILED STEPS
Command or Action
Purpose
Step 1
Apply power to the second LCC.
Starts up the LCC. 
Allow the chassis to fully boot. 
Verify that “IOS XR RUN” appears on the RP 
faceplates.
In each FCC, verify that the indicator LED on the OIM 
LED panel is green for each fabric cable connected to 
the non-DSC LCC.
The LCC loads any necessary software and 
configurations from the DSC, including the rack 
number and appropriate Cisco IOS XR software 
packages.
Do not proceed until both RPs in the LCC display 
“IOS XR RUN.” This indicates that the RP has 
successfully loaded the Cisco IOS XR software. 
Step 2
show controllers fabric rack all detail
Example:
RP/0/RP0/CPU0:router(admin)# show controllers 
fabric rack all detail
Displays the status of all racks in the system. 
In a properly operating system, the rack status for all 
racks should be Normal, and the server status should be 
Present.
Step 3
show controllers fabric plane all detail
Example:
RP/0/RP0/CPU0:router(admin)# show controllers 
fabric plane all detail
Displays the status of all racks and additional information 
for racks in install mode.
Wait for the status in the Admin State and Oper State 
columns to change to UP for all planes.
Step 4
show controllers fabric connectivity all detail
Example:
RP/0/RP0/CPU0:router(admin)# show controllers 
fabric connectivity all detail
Displays the LCC cards that can communicate with all eight 
fabric planes. 
The expected output should contain a series of ‘1’s for 
each of the fabric planes active in the system. If a fabric 
plane is administratively “shutdown” the output of the 
command above remains the same. If the fabric card is 
physically removed or powered down, the “1” changes 
to “.”