Cisco Systems CISCO7201 Manual De Usuario

Descargar
Página de 166
A-2
Cisco 7201 Installation and Configuration Guide 
OL-11364-04
Appendix A      Specifications
Power Supply Product Numbers
Power Supply Product Numbers
Dual AC Power Supply Information (continued)
AC-input voltage rating
100–240 VAC
2
AC-input current rating 
2A
3
 maximum
AC-input current (typical)
0.85A at 100 VAC
 
0.35A at 240 VAC
AC-input frequency rating
50 to 60 Hz
4
AC-input cable
Use only Cisco Agency-approved power cords
Dual DC Power Supply Information
DC-input power 
150W maximum
DC- input power (typical)
85W
DC-input nominal voltage rating
–48 VDC
5
 to –60 VDC
DC-rated input voltage
–40 VDC to –72 VDC
DC-input current rating
6A maximum
DC-input current (typical)
1.8A at –48 VDC, 1.4A at –60 VDC
DC-input cable
16-AWG
6
 (1.0 mm2) or 18-AWG (0.75 mm2) wire with a circuit breaker rating of 20A 
maximum. The ground wire must be at least as large as the supply wires.
1.
BTU = British thermal units
2.
VAC = volts alternating current
3.
A = amperes
4.
Hz = hertz
5.
VDC = volts direct current
6.
AWG = American Wire Gauge
Table A-2
Power Supply Product Numbers
Power Supply
Product Number
AC power supply
PWR-7201-AC=
1
1.
This product number provides a single AC power supply.
DC power supply
PWR-7201-DC=
2
2.
This product number provides a single DC power supply.
Table A-1
Cisco 7201 Router Specifications (continued)
Description
Specification