Cisco Systems Cisco CRS-1 Manual De Usuario

Descargar
Página de 146
   
4-29
Cisco CRS-1 Carrier Routing System 4-Slot Line Card Chassis Installation Guide
OL-10971-07
Chapter 4      Installing and Removing SFCs, RPs, MSCs, PLIMs, and Associated Components
How to Install or Remove a Route Processor Card
Step 10
To fully seat the card in the midplane connector, grasp both card ejector levers simultaneously, then push 
them both inward until they are flush against the front edge of the card carrier. After the guide pins make 
contact, continue pushing the card carrier until the card ejector levers begin pivoting forward.
Caution
Verify that the openings on the card ejector cams pass over the tabs; otherwise, one or both 
ejector levers may bind when you attempt to close the levers, thereby damaging or breaking 
one or both.
Step 11
To seat the card firmly in the slot, use the screwdriver to tighten the captive screws.
Note
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and 
safety, connect the Ethernet interfaces only to intrabuilding or nonexposed wiring or cabling. 
The intrabuilding cable must be shielded and the shielding must be grounded at both ends.
What to Do Next
After performing this task:
  •
Place the impedance carrier in an antistatic bag for storage and future use. 
  •
Verify that the card has been installed properly (see the 
). 
  •
Connect the console port and LAN port. For more information, see the latest release of the Cisco 
IOS XR Getting Started Guide
 on www.cisco.com.
  •
If you are performing the initial installation of the system, install the MSCs (see the 
).
Removing an RP Card
This section describes how to remove a route processor (RP) card from the chassis. For more detailed 
information on the route processor card, see Cisco CRS-1 Series Carrier Routing System 4-Slot Line 
Card Chassis System Description
Every Cisco CRS-1 4-slot line card chassis contains two route processor cards in dedicated slots on the 
front (PLIM) side of the chassis (see 
).
Note
For enhanced immunity to external electromagnetic disturbance levels of 10 V per meter and 10 V RMS, 
you must use a shielded Ethernet (CAT5 or better STP) cable on the Management Ethernet connection 
of the RP card.