 Trunk Cards 4-43
Network Trunk Module
Figure 4-25
BC-SR Faceplate
Table 4-19
BC-SR Connections and Status LEDs
Connection/Indicator
Function
EIA/TIA-449 data connector
DB-37 female connector
X.21 data connector
DB-15 female connector
V.35 data connector
34-pin female MRAC connector
LOS light (red)
Loss of signal at the local end
Bad CLK light (red)
Loss of clock or clock out of range
Yellow alarm light (yellow)
Loss of packet alignment (NTM) or frame alignment at remote end
DSR light (green)
The DSR lead is high (ON)
DTR light (green)
The DTR lead is high (ON)
RXD light (green)
The receive data line shows activity
TXD light (green)
The transmit data line shows activity
Fail light (red)
An error occurred. First, reset the card with resetcd f. If the LED comes on
again, contact the Cisco TAC through Customer Engineering
Active: light (green)
The card is in service and has active circuits
BC-SR
RS 449/MIL188
X.21
V.35
Fail (red)
H8318
Active (green)
LOS (red)
Bad Clk (red)
Yellow alarm (yellow)
DSR (green)
DTR (green)
RXD (green)
TXD (green)