Cisco Systems ASR 1000 Series Manual De Usuario

Descargar
Página de 292
8-31
Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Chapter 8      Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units
  Removing and Replacing a Cisco ASR 1004 Router Power Supply
Figure 8-22
Cisco ASR 1006 Router DC Power Supply Terminal Block Plastic Cover and Switch
Step 12
Remove the tape from the circuit-breaker On/Off switch.
Step 13
Switch the circuit breaker On/Off switch to the On (|) position.
Note
The requirement for maximum torque applied to the power or ground Kepnuts must be 8 in-lb when the 
power or ground lug is not present. 
This completes the procedure for installing the DC power supply into the Cisco ASR 1006 Router.
Removing and Replacing a Cisco ASR 1004 Router Power 
Supply
This section provides information about removing and replacing the following power supplies in a Cisco 
ASR 1004 Router:
  •
AC power supply
  •
DC power Supply
Removing the AC Power Supply from Cisco ASR 1004 Router
Because of the power supply redundancy, there is no need to power off the Cisco ASR 1004 Router 
before removing one of the AC power supplies.
1
DC power supply On/Off switch
2
 Terminal block plastic cover black screw
OFF
55
-48/-60V         4
0A
280026
1
2