Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Chapter 8      Replacing Cisco ASR 1000 Series Routers Field-Replaceable Units
  Removing and Replacing a Cisco ASR 1002 Router Power Supply
Figure 8-32
Cisco ASR 1002 Router Improper AC Power Cord Cabling
Note
Using a tie wrap for the AC power cable is optional and not necessary. However, if you do attach 
the AC power cable to a power supply tab and then you remove the AC power cable for some 
reason, check for any damage to the cable after you cut the tie wrap off. If the power cord is 
damaged, replace it immediately.
Step 4
Plug the AC power supply cable into the AC power source.
Note
Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The 
system fans are inside the power supply units and must spin for cooling. Because all the system 
fans can be powered by one power supply, the second power supply unit does not have to be 
powered on, but it must be installed.
Caution
If you remove a power supply, the system can run for a maximum of five minutes before the system shuts 
down. The fans and power elements are independent within the power supply. Therefore, it is not 
required that the replacement power supply be energized within five minutes. The only requirement is 
that the power supply be installed in the chassis, which energizes the fans and maintains proper system 
cooling. 
This completes the procedure for installing the AC power supply in the Cisco ASR 1002 Router.
Removing and Installing a DC Power Supply in Cisco ASR 1002 Router
This section provides information about removing and installing a DC power supply in the Cisco 
ASR 1002 Router.
Warning
When you install the unit, the ground connection must always be made first and disconnected last. 
Statement 1046
280378
OUTPUT INPU
T
FAIL
OK
OK
FAN
This unit might have m
ore than
one power supp
ly connection.
All connections must
 be remove
d
to de-energize the 
unit.
OUTPUT INPU
T
FAIL
OK
OK
FAN
This unit might
 have more than
one power supp
ly connection.
All connections m
ust be remove
d
to de-ene
rgize the unit.