Cisco ASR 1000 Series Aggregation Services Routers Hardware Installation and Initial Configuration Guide
OL-13208-03
Appendix B      Troubleshooting Initial Startup Problems
  General Troubleshooting Tips
Troubleshooting the Cooling Subsystem
Check the following to help isolate a problem with the cooling subsystem:
System powers off, 
no STATUS LED, 
and no operating 
fans.
Power supply failure.
If the system is operating with only one 
power supply, it powers off after five 
minutes. If this occurs, you must remove 
all power cables from the power supply 
for at least 30 seconds before the power 
supply can be powered back up.**
Contact a service representative.
** Two power supplies must be installed in the chassis at all times to ensure sufficient cooling. The system fans are inside the 
power supply units and must spin for cooling. Because all the system fans can be powered by one power supply, the second 
power supply unit does not have to be powered on, but it must be installed.
Caution
If you remove a power supply, the system can run for a maximum of five minutes before the 
system shuts down. The fans and power elements are independent within the power supply. 
Therefore, it is not required that the replacement power supply be energized within five 
minutes. The only requirement is that the power supply be installed in the chassis, which 
energizes the fans and maintains proper system cooling. 
Table B-2
Troubleshooting the Power System (continued)
Symptom
Possible Cause
Possible Solution
Table B-3
Troubleshooting the Cooling Subsystem 
Symptom 
Possible Cause
Possible Solution
System shuts down, some fans may or may 
not continue to rotate, and this error 
message is displayed:
Queued messages:
%ENVM-1-SHUTDOWN: Environmental 
Monitor initiated shutdown
This error message indicates that the system 
has detected an overtemperature condition 
or out-of-tolerance power condition inside 
the chassis.
  •
One or more fans are not 
operating.
  •
The fans are operating too 
slowly.
  •
The power supply is not 
operating.
To determine if the fans are 
operating, listen for them. In noisy 
environments, place your hand on the 
rear of the chassis to feel if air is 
being forced out the vents.
Contact a service 
representative.
Multiple fan failure 
Red indicates failed fan status
Amber indicates the Cisco ASR 1000 Series 
Route Processor 1 status
Fan speed dropped below its fan fail 
speed
  •
Identify and 
log the failed 
fan PEM 
location.
  •
Recommend 
immediate 
replacement 
of PEM.