Cisco Systems OL-7396-01 Manual De Usuario

Descargar
Página de 934
7-39
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 7
Configuring Virtual Connections
Configuring Two-Ended Soft PVC and Soft PVP Connections
Configuring Two-Ended Soft PVC Connections
To configure a two-ended soft PVC connection, follow these steps:
.
Note
The default value for the upc option is pass.
Note
The default value for the pd option is use-cttr.
Note
For VBR-nrt and VBR-rt service categories you must configure the MBS (even if the value is default) 
in the ATM connection traffic table row attached to the passive leg.
Note
You can use the debug atm sig-soft (interface) and debug atm rm events commands to get information 
on why a passive leg is not used due to traffic parameter mismatches.
Command
Purpose
Step 1
Switch-C(config)# atm filter-set name [index 
[number]] [permit | deny] [template | time-of-day 
{anytime | start-time {end-time}}]
(Optional) Used to configure the access-control 
filter-set parameter in on the passive 
destination-side of the soft VC.
Step 2
Switch-C(config)# interface atm 
card/subcard/port
Switch-C(config-if)# 
Selects the interface, on the terminating switch, 
being configured.
Step 3
Switch-C(config-if)# atm soft-vc dest-vpi 
dest-vci 
passive [pd pd] [upc upc] [rx-cttr index
[tx-cttr index] [access-control {src-address 
atm-address | filter-set name}]
Configures the passive leg on the terminating 
switch interface.
Step 4
Switch-B(config-if)# atm soft-vc source-vpi 
source-vci dest-address atm-address dest-vpi 
dest-vci
 [enable | disable] [upc upc] [pd pd
[rx-cttr index] [tx-cttr index] [retry-interval 
[first retry-interval] [maximum retry-interval]]
Creates a two-ended soft PVC on the source 
switch that uses the passive half leg on the 
terminating switch.
Step 5
Switch-C(config-if)# end
Switches to EXEC command mode.
Step 6
Switch-C# show atm vc interface atm 
card/subcard/port vpi vci
Displays the passive half-leg configuration 
information of two-ended soft PVC.