Cisco Systems OL-7396-01 Manual De Usuario

Descargar
Página de 934
7-43
ATM Switch Router Software Configuration Guide
OL-7396-01
Chapter 7
Configuring Virtual Connections
Configuring Access Filters on Soft PVC and Soft PVP Passive Connections
The access filters for soft PVC and soft PVP passive connections feature uses the access-control 
parameter, to restrict access to the passive destination side of the soft PVC or soft PVP based on the 
source interface NSAP address of the connection and time of day. 
You configure a filter set using the atm filter-set command on the passive soft PVC or soft PVP side. 
Configuring a filter set gives you the added flexibility to allow multiple NSAP addresses to access the 
passive destination side of the soft PVC or soft PVP and limit the time of day when to allow access. The 
examples later in this section show access control configured using both source ATM address and filter 
set configurations.
Configuring Access Filters on Soft PVC Passive Connections
To configure a access filters on a two-ended soft PVC passive connection, follow these steps:
.
Examples
Using a source address — The following example shows the configuration of the two-ended soft PVC 
(shown in 
) with access control configured using a source address on the passive half leg. Start 
with the configuration of Switch-C.
Switch-C(config)# interface atm atm 0/0/1
Switch-C(config-if)# atm soft-vc 1 60 passive access-control src-address 
47.0091.8100.0000.0010.073c.0101.4000.0c80.9030.00
Switch-C(config-if)# end
Switch-C# 
On Switch-B, create a two-ended soft PVC on the source switch that uses the passive half leg on the 
terminating switch.
Switch-B(config)# interface atm 3/0/1
Switch-B(config-if)# atm soft-vc 0 50 dest-address 
47.0091.8100.0000.0001.4204.d801.4000.0c85.8000.00 1 60
Command
Purpose
Step 1
Switch-C(config)# atm filter-set name [index 
[number]] [permit | deny] [template | time-of-day 
{anytime | start-time {end-time}}]
(Optional) Used to configure the access-control 
filter-set parameter in on the passive 
destination-side of the soft VC.
Step 2
Switch-C(config)# interface atm 
card/subcard/port
Switch-C(config-if)# 
Selects the interface, on the terminating switch, 
being configured.
Step 3
Switch-C(config-if)# atm soft-vc dest-vpi 
dest-vci 
passive [pd pd] [upc upc] [rx-cttr index
[tx-cttr index] [access-control {src-address 
atm-address | filter-set name}]
Configures the passive leg on the terminating 
switch interface.
Step 4
Switch-B(config-if)# atm soft-vc source-vpi 
source-vci dest-address atm-address dest-vpi 
dest-vci
 [enable | disable] [upc upc] [pd pd
[rx-cttr index] [tx-cttr index] [retry-interval 
[first retry-interval] [maximum retry-interval]]
Creates a two-ended soft PVC on the source 
switch that uses the passive half leg on the 
terminating switch.
Step 5
Switch-C(config-if)# end
Switches to EXEC command mode.
Step 6
Switch-C# show atm vc interface atm 
card/subcard/port vpi vci
Displays the passive half-leg configuration 
information of two-ended soft PVC.