Compaq FTAM Responder Diagnostic Messages
A- 7
Association-Related Diagnostic Messages
access is less than the number of services in the group.  (Only the file-access service 
class allows a threshold of less than the number of services in the group, allowing a 
group of primitives to provide some service even if one of the primitives fails.)
Effect. The responder aborts the association.
Recovery. The application or FTAM user should discard the association context, 
reestablish the association, and retry the operation with a group having the proper value 
for the threshold parameter.
1017
Cause. A service has been attempted that is inconsistent with the current requested 
access.
Effect. The responder does not perform the service.
Recovery. The application or FTAM user should reselect the file with the required 
requested access and retry.  If the problem persists, the Compaq problem solver can use 
the SCF TRACE command and the PTrace utility to troubleshoot the problem.  For more 
information on tracing and troubleshooting, refer to the OSI/FTAM Configuration and 
Management Manual
.Association-Related Diagnostic Messages
Association-Related Diagnostic Messages
Table A-5 displays the diagnostic error identifiers related to managing associations.
Specific PDU request inconsistent with the current requested access
Table A-5. Association-Related Diagnostic Messages
Identifier
Type
Observer
Source
Reason
2002
2
4
1
Unsupported service class
2003
2
4
1
Unsupported functional unit
2013
0
4
2
Checkpoint  window error 
(unsupported)
2014
0
3
2
Communications  ftam-quality-
of-service not supported
2015
2
5
1
Initiator identity unacceptable
2016
0
4
1
Context  management  refused
2018
0
5
1
Contents  type  list  cut  by 
responder
2020
2
5
1
Invalid  file  store  password
2021
2
4
1
Incompatible  service  classes