Delta Electronics DUP-B Manual De Usuario

Descargar
Página de 491
 
Chapter 3 Creating and Editing Screens 
Revision May, 2010 
 
 
3-135 
Property Description of Range Indicator Element 
Foreground Color 
Style 
(Please refer to Table 3-8-2 Property Description of General 
Buttons.) 
Add/Remove 
 State 
It is used to set the state numbers of range indicator. 1~256 states 
can be set.   
 
Data Length: 
There are 16bits Word and 
32bits Double Word two 
options. 
 
Memory Format: 
here are following data format 
provided: 
Word/Double Word 
1. BCD 
2. Signed 
BCD 
3. Signed 
Decimal 
4. Unsigned 
Decimal 
 
Selecting this option can use default 5 states to 
set the range. If there is n numbers of states, it 
indicates that there is Range n-1 for the user to 
use. The user can specify the foreground color of 
state 0, 1, 2, 3, and 4 as red, green, blue, yellow 
and purple respectively.   
Constant 
Limits 
Range 0 
Range 1 
Range 2 
Range 3 
100 50  33  1 
 
 
When the value of read address is higher than 
100, the range indicator will display in red. When 
the value of the read address is higher than 50, 
the range indicator will display in green, and vise 
versa. 
Detail  
Range   
Variable 
Limits 
When this option is selected, there is Range n-1 
for the user to use. n represents the total state 
numbers and n-1 represents the total range 
numbers. For example, if the read address is $0, 
and the total state number of the element is 5, it 
indicates that there is Range 0~4 for the user to 
use. Then, the lower limit value of Range 0 is $1, 
the lower limit value of Range 1 is $2 and vise 
versa.