Property Description of Static Graphic Element 
No 
When this option is selected, the value of the read 
address will be regarded as the state number. It means 
that the state number is determined by the value of the 
read address. For example, if the value of the read 
address $0 is 0, it will switch to 0th state; if the value of 
the read address $0 is 5, it will switch to 5th state.   
Yes 
When this option is selected and the value of the read 
address is a non-zero value, the static graphic element 
will change automatically. For example, if the value of 
the read address $0 is 1 and higher (a non-zero value), 
the element will change the picture automatically 
according to the change time that the user set. When 
the value of the read address $0 is set to 0, the static 
graphic element will be back to the initial state and will 
not change the picture automatically.   
Auto Change   
Variation 
When this option is selected, the property of the Read 
Address will be the condition of changing element 
picture. The element will change the picture 
automatically according to Read Address+1. For 
example, if $0 is set to display the address of the 
element and $1 is set to change the element picture, 
when the value of the read address $1is 0, the user 
needs to use the read address $0 to switch the state of 
the static graphic element. At this time, the static 
graphic element will not change automatically, like 
when “No” option is selected. When $1 is 1 and higher (a 
non-zero value), the static graphic element will change 
the picture automatically, like when “Yes” option is 
selected.