Chapter 3 Creating and Editing Screens 
 
3-162 
Revision May, 2010
 
Property Description of Character Entry Elements 
Character Length The range is with 1 ~ 28 words. The default setting is 4words.
 
Trigger 
Trigger Type 
The user can use this setting to trigger the designated controller 
address to be ON before or after writing the setting value. Please 
note that this function can only trigger the controller address to be 
ON. If the controller address needs to be triggered again, the user 
should set the address to be OFF manually. 
When the input mode is Touch Popup, the user can define the style 
of the keypad, including title, font, font size, font color and keypad 
color. The position that the system keypad cannot display will be 
placed in the center of the screen.   
 
Edit System 
Keypad 
 
Adjust the system keypad size 
 
Set the height of the title bar 
 
Set the font size 
 
Set the font 
 
Set the font color 
 
Set the background color 
 
Return to the default setting 
 
Input Mode 
There are Touch Popup, Active Non-Popup and Touch Non-Popup 
three options. The default setting is Touch Popup. For the 
description of Active Non-Popup and Touch Non-Popup mode, 
please refer to section 3.8.14 Keypad Elements. 
 
User Security 
Level 
Use this option to set the user priority for pressing this element. 
Only the priority that is equal to or higher than the current setting 
can use this element.