5.2 
USB-CDC Setup  
The following steps provide a check on the USB-CDC COM port selected by the 
operating system.  This step is used only if there is a need to confirm operation and 
possible to review the communication port number.  Open the Windows Control Panel 
and follow the selections: System, Hardware Tab, and Device Manager.  Expand the 
Port (COM & LPT) folder.  There should be an item “IDTECH USB-RS232 uSign (COM 
#)”, where # is a Port number.  uSign is set-up and communicating. 
 
 
6.0 Specifications 
6.1 Power 
requirement 
Voltage 
 
uSign 100 is 9VDC and uSign 200 is 5VDC  
Current   150mA 
typical 
RS232 Power 
AC adapter, center positive adaptor plug output 
USB Power   
Host USB port 
6.2 
Physical housing uSign 100 
Overall size 
113mm wide 
77.5mm high 
31.5mm thick including back plate 
Display  
3.3-inch diagonal signature area  
Copyright © 2006, International Technologies & Systems Corp. All rights reserved. 