Viewing diagnostic information
DSLPipe DSU (SDSL) User’s Guide
3-5
Viewing diagnostic information
After you set up the communications software and the DSLPipe unit’s 
configuration menu appears (see Figure 3-1), you can press 
4
 to enter debug 
mode and view diagnostic information. When you press 
4
, the following window 
appears:
Figure 3-2.  Debug Mode window
At the 
Select Function Items
 prompt, press 1 to display the HDLC 
registers. Table 3-2 describes the fields that display in the list that appears.
V.35 ch Tx CRC
Shows either 
Enable
 or 
Disable
. The default is 
Enable
This means that the CRC is appended to the end of the frame 
when data is sent over the V.35 line.
V.35 ch RxC 
Polarity
Indicates 
Norm
 (Normal) or 
Rev
 (Reverse). The default is 
Norm.
This means that data will be sampled at the rising edge 
of the clock.
V.35 ch TxC 
Polarity
Indicates 
Norm
 (Normal) or 
Rev
 (Reverse). The default is 
Norm.
This means that data will be shifted out of the buffer at 
the falling edge of the clock.
Table 3-1. Fields in the DSLPipe status window (Continued)
Fields
Description
SDSL V.35 DSU
Debug Mode
0. Return to Main Menu
1. Check HDLC Registers
2. Print Rx Data