Adtran 1200305L1 Manual De Usuario
ATLAS 550 System Manual
Section 4, User Interface Guide
61200305L1-1F
© 2002 ADTRAN, Inc.
237
D
EDICATED
M
APS
(E1/PRA N
ETWORK
I
NTERFACE
)
D
EDICATED
M
APS
(E1/PRA) > C
REATE
/E
DIT
M
APS
> C
ONNECTS
Write security: 3; Read security: 5
Enters the dedicated map connections. Press <Enter> to activate the submenus.
D
EDICATED
M
APS
(E1/PRA) > C
REATE
/E
DIT
M
APS
> C
ONNECTS
> T
O
/F
ROM
C
ONFIG
Write security: 3; Read security: 5
Specifies the configuration for the
T
O
/F
ROM
connection. The following selections may apply to the
E1/PRA Network Interface Module, depending on the application:
T1 T
RUNK
C
ONDITIONING
S
ERVICE
Write security: 3; Read security: 5
Sets known values in the signaling bits and the data field for outgoing DS0s which are
cross-connected to a T1 port experiencing alarms.
The trunk conditioning process consists of a 2.5 second transmission (indicating call termination),
followed by a continuous transmission signaling the final condition as chosen by the user. This
selection is only valid for T1 ports having
cross-connected to a T1 port experiencing alarms.
The trunk conditioning process consists of a 2.5 second transmission (indicating call termination),
followed by a continuous transmission signaling the final condition as chosen by the user. This
selection is only valid for T1 ports having
RBS
set to
O
N
.
This option defines to ATLAS 550 the type of signaling being used on the trunk:
E&M, LS/GS
N
ETWORK
OR
U
SER
, SW56,
or
C
USTOM
.
T1 T
RUNK
C
ONDITIONING
S
TATE
Write security: 3; Read security: 5
(Available only when
T1 T
RUNK
C
ONDITIONING
S
ERVICE
is enabled.) Defines the final fault signaling
state.
I
DLE
Used for one-way trunks; that is, for outgoing or incoming calls only –
not both.
not both.
S
EIZED
Used for two-way trunks. Prevents connected equipment from
attempting to use a failed trunk for an outgoing call.
attempting to use a failed trunk for an outgoing call.
T1 F
AULT
S
IGNALING
Write security: 3; Read security: 5
(Available only when
T1 T
RUNK
C
ONDITIONING
S
ERVICE
is enabled.) Displays the final fault signaling
state of the AB bits. This field is read-only unless
C
USTOM
is chosen for the
T1 T
RUNK
C
ONDITIONING
S
ERVICE
option.
T1 T
ROUBLE
C
ODE
V
ALUE
Write security: 3; Read security: 5
(Available only when
T1 T
RUNK
C
ONDITIONING
S
ERVICE
is enabled.) Displays the Hex value of the 2.5
second pre-alarm transmission.